Highlighted Data from Publications using CBIO's Automated Lateral Flow Reagent Dispenser (ALFRD):
Title : Lectin-based Lateral Flow Assay: Proof-of-Concept
Year : 2016
Journal : Analyst
Authors : Damborsky P, Koczula KM, Gallotta A, Katrlik J
Institution Affiliations : Slovak Academy of Sciences; Xeptagen SpA
eference : Analyst. 2016. 141(23) 6444–6448. doi : 10.1039/C6AN01746K # Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : Mitigating the Hook Effect in Lateral Flow Sandwich Immunoassays using Real-time Reaction Kinetics
Year : 2017
Journal : Analytical Chemistry
Authors : Rey EG, O’Dell D, Mehta S, Erickson D
Institution Affiliations : Cornell University
Reference : Analytical Chemistry. 2017. 89(9): 5095-5100. doi : 10.1021/acs.analchem.7b00638
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
T itle : Multiplexed Recombinase Polymerase Amplification Assay To Detect Intestinal Protozoa Year : 2016
Journal : Analytical Chemistry
Authors : Crannell Z, Castellanos-Gonzalez A, Gayatri N, Rojelio M, White AC, Richards- Kortum A
Institution Affiliations : University of Texas Medical Branch; Baylor College of Medicine; Rice University
Reference : Analytical Chemistry. 2016. 88 , 1610-1616; doi:10.1021/acs.analchem.5b03267
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays
Year : 2015
Journal : Analytical Chemistry
Authors : Adhikari M, Strych U, Kim J, Goux H, Dhamane S, Poongavanam MV, Hagström AEV, Kourentzi K, Conrad JC, Willson RC
Institution Affiliations : University of Houston; Centro de Biotecnología FESMA, Tecnol ó gico de Monterrey
Reference : Analytical Chemistry. 2016. 87, 11660-11665; doi:10.1021/acs.analchem.5b00702
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : IronPhone: Mobile Device-Coupled Point-of-Care Diagnostics for Assessment of Iron Status by Quantification of Serum Ferritin
Year : 2017
Journal : Biosensors and Bioelectronics
Authors : Srinivasan B, O’Dell D, Finkelstein JL, Lee S, Erickson D, Mehta S
Institution Affiliations : Cornell University
Reference : Biosensors and Bioelectronics. 2017. 99(15): 115-121 . https://doi.org/10.1016/j.bios.2017.07.038 # Automated Lateral Flow Reagent Dispenser (ALFRD) ™
Title : Rapid Detection of Escherichia coli O157 and Shiga Toxins by Lateral Flow Immunoassays
Year : 2016
Journal : Toxins
Authors : Wang J, Katani R, Li L, Hegde N, Roberts EL, Kapur V, DebRoy C
Institution Affiliations : Pennsylvania State University
Reference : Toxins. 2016. Mar 25; 92(8) . doi:10.3390/toxins8040092
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : Persistent Luminescence Strontium Aluminate Nanoparticles as Reporters in Lateral Flow Assays
Year : 2014
Journal : Analytical Chemistry
Authors : Paterson AS, Raja B, Garvey G, Kolhatkar A, Hagström AEV, Kourentzi K, Lee TR, Willson RC
Institution Affiliations : University of Houston
Reference : Analytical Chemistry. 2014. 86(19) . doi:10.1021/ac5012624
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : NutriPhone: A Mobile Platform for Low-Cost Point-of-Care Quantification of Vitamin B12 Concentrations
Year : 2016
Journal : Nature Scientific Reports
Authors : Lee S, O’Dell D, Hohenstein J, Colt S, Mehta S, Erickson D
Institution Affiliations : Cornell University
Reference : Nature Scientific Reports. 2016. Jun 15; 6:28237. doi:10.1038/srep28237
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title: Towards a Point-of-Care strip Test to Diagnose Sickle Cell Anemia
Year : 2017
Journal : PLoS One
Authors : Bond M, Hunt B, Flynn B, Huhtinen P, Ware R, Richards- Kortum R
Institution Affiliations : Rice University; PerkinElmer; Cincinnati Children’s Hospital Medical Center
Reference : PLoS One. 2017. May 16. https://doi.org/10.1371/journal.pone.0177732
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : Sensitive Detection of Norovirus Using Phage Nanoparticle Reporters in Lateral-Flow Assay
Year : 2015
Journal : PLoS ONE
Authors : Hagström AEV, Garvey G, Paterson AS, Dhamane S, Adhikari M, Estes MK, Strych U, Kourentzi K, Atmar RL, Willson RC
Institution Affiliations : University of Houston; Baylor College of Medicine; Houston Methodist Research Institute
Reference : PLoS One. 2015. 10 (5). 1-11; doi:10.1371/journal.pone.0126571
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Title : Simple System for Isothermal DNA Amplification Coupled to Lateral Flow Detection
Year : 2013
Journal : PLoS ONE
Authors : Roskos K, Hickerson AI, Lu H-W, Ferguson TM, Shinde DN, Klaue Y, Niemz A
Institution Affiliations : Keck Graduate Institute; Claremont BioSolutions
Reference : PLoS ONE. 2013 . 8 (7): e69355.; doi:10.1371/journal.pone.0069355
# Automated Lateral Flow Reagent Dispenser (ALFRD)™
Key Features
• Reproducible, well defined test lines • No heating of reagents • Non-contact, adjustable dispense tips • Dispense colloidal conjugate or viscous solutions • Interchangeable and low-cost dispense heads and tips • Adjustable dispense volume • Simultaneous dispensing of up to 4 lines (customizable for additional lines) • Accommodates 30 cm membrane length of varying width • Use your existing syringe pump or purchase from ClaremontBio • Coming Soon: Adaptable to dispense dots for flow-through assays Video Protocol:
VIDEO User Manual: ClaremontBio's Lateral Flow Reagent Dispenser User Manual (Opens as a PDF...make sure your browser allows pop ups)